<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>دانشگاه پیام نور</PublisherName>
				<JournalTitle>فصلنامه علمی  زیست شناسی جانوری تجربی</JournalTitle>
				<Issn>2322-2387</Issn>
				<Volume>3</Volume>
				<Issue>2</Issue>
				<PubDate PubStatus="epublish">
					<Year>2015</Year>
					<Month>02</Month>
					<Day>20</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Evaluation of Biochemical Parameters in Sheep after Placement of Tissue Engineered Valve in Thoracic Aorta</ArticleTitle>
<VernacularTitle>ارزیابی تابلوی بیوشیمیایی خون درگوسفندان تحت جراحی پیوند دریچه آئورت مهندسی شده در آئورت توراسیک</VernacularTitle>
			<FirstPage>31</FirstPage>
			<LastPage>37</LastPage>
			<ELocationID EIdType="pii">1481</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>حمید</FirstName>
					<LastName>توانایی منش</LastName>
<Affiliation>استادیار ، گروه بیماری های داخلی، دانشکده دامپزشکی دانشگاه تهران، تهران،</Affiliation>

</Author>
<Author>
					<FirstName>محمدرضا</FirstName>
					<LastName>مخبر دزفولی</LastName>
<Affiliation>استاد، گروه بیماری های داخلی، دانشکده دامپزشکی دانشگاه تهران، تهران،</Affiliation>

</Author>
<Author>
					<FirstName>عبدالمحمد</FirstName>
					<LastName>کجباف‌زاده</LastName>
<Affiliation>استاد، گروه ارولوژی، مرکز تحقیقات ارولوژی اطفال، بیمارستان مرکز طبی کودکان، دانشگاه علوم پزشکی تهران، تهران</Affiliation>

</Author>
<Author>
					<FirstName>محمد مهدی</FirstName>
					<LastName>دهقان</LastName>
<Affiliation>دانشیار، گروه جراحی و رادیولوژی، دانشکده دامپزشکی دانشگاه تهران، تهران</Affiliation>

</Author>
<Author>
					<FirstName>حسین</FirstName>
					<LastName>احمدی تفتی</LastName>
<Affiliation>استاد، مرکز قلب تهران، دانشگاه علوم پزشکی تهران، تهران</Affiliation>

</Author>
<Author>
					<FirstName>میر سپهر</FirstName>
					<LastName>پدرام</LastName>
<Affiliation>استادیار ، گروه جراحی و رادیولوژی، دانشکده دامپزشکی دانشگاه تهران، تهران</Affiliation>

</Author>
<Author>
					<FirstName>فرزاد</FirstName>
					<LastName>حیاتی</LastName>
<Affiliation>دانشجوی سابق دکترا، گروه جراحی و رادیولوژی، دانشکده دامپزشکی دانشگاه تهران، تهران</Affiliation>

</Author>
<Author>
					<FirstName>مسعود</FirstName>
					<LastName>تقی زاده جاهد</LastName>
<Affiliation>دانشجوی سابق دکترا، گروه جراحی و رادیولوژی، دانشکده دامپزشکی دانشگاه تهران، تهران</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2015</Year>
					<Month>03</Month>
					<Day>11</Day>
				</PubDate>
			</History>
		<Abstract>Valvular diseases are a common problem and valvular replacement is usual treatment for valvular destruction. Tissue engineered heart valve has some advantages, that make them an interesting alternative for previous valves. The aim of this study is measurement of biochemical factors for evaluation of short term efficacy of tissue engineered heart valve. This study was undertaken on 5 male sheep with average weight of 45-55 kg. They have been of-feed 24 hours before of operation. The tissue engineered heart valves were placed in thoracic aorta and after surgery they connected to ventilator under SIMV mode. The arterial blood sample Were collected every hours for 12 hours and evaluated, PCO&lt;sub&gt;2&lt;/sub&gt;, PO&lt;sub&gt;2&lt;/sub&gt;, tCO&lt;sub&gt;2&lt;/sub&gt;, SO&lt;sub&gt;2&lt;/sub&gt;, Hct, Na&lt;sup&gt;+ &lt;/sup&gt;and K&lt;sup&gt;+&lt;/sup&gt;. Arterial blood sample has been taken from auricularis artery. Blood pH fell down in all sheep after surgery but in two sheep as a result of sever blood loos during surgery pH went up toward acidosis, finally after 12 hours pH in all sheep was in normal range. After operation PCO&lt;sub&gt;2&lt;/sub&gt; was low an PO&lt;sub&gt;2&lt;/sub&gt; was high because of mechanical ventilation. All the factors backed to normal range after 12 hours of operation. This study shows that biochemical factors had fluctuation in first 12 hours but after 12 hours most of them backed to normal range. &lt;br /&gt;  &lt;br /&gt;&lt;br /&gt;</Abstract>
			<OtherAbstract Language="FA">به دلیل معایب پروتزهای دریچه­ای مکانیکی و زیستی، استفاده از روش­های مهندسی بافت جهت ساخت دریچه­هایی با کارایی بهتر مورد توجه است. ارزیابی تغییرات تابلوی بیوشیمیایی خون به عنوان فاکتورهای ارزشمند در ارزیابی کارآیی اولیه دریچه­های مهندسی شده. این مطالعه در 5 رأس گوسفند نر سالم با وزن میانگین 45-55 کیلوگرم انجام شد. ابتدا دریچه­ با باز کردن قفسه صدری در ناحیه آئورت توراسیک حیوانات کار گذاشته ­شد. سپس گوسفندان به ونتیلاتور ICU متصل شده و پس از بازگشت به شرایط طبیعی به صورت مداوم مانیتور شدند. و هر ساعت مورد معاینه بالینی قرار گرفتند و همچنین نمونه خون شریانی جهت ارزیابی تابلوی بیوشیمیایی اخذ و توسط دستگاه آنالیزور گازهای خونی بررسی ­شدند.فاکتورهای مورد نظر شامل: pH، PCO&lt;sub&gt;2&lt;/sub&gt;، PO&lt;sub&gt;2&lt;/sub&gt;، tCO&lt;sub&gt;2&lt;/sub&gt;، SO&lt;sub&gt;2&lt;/sub&gt;، Hct، Na&lt;sup&gt;+&lt;/sup&gt; و K&lt;sup&gt;+&lt;/sup&gt; بودند.میزان pH در همه گوسفندان ابتدا افزایش چشمگیر داشت و در دو رأس گوسفند به دلیل خونریزی وسیع به سمت اسیدوز رفت و نهایتا در همه گوسفندان پس از 12 ساعت به حالت طبیعی بازگشت. میزان PCO&lt;sub&gt;2&lt;/sub&gt; در تمام حیوانات در ساعات اولیه پس از جراحی کمتر از میزان طبیعی بوده و با گذشت زمان به تدریج به حالت طبیعی باز گشت. سایر فاکتورها نیز با گذشت زمان به حالت طبیعی بازگشتند. نتایج این مطالعه نشان داد که اگر چه فاکتورهای مد نظر، در طول مطالعه نوسانات فراوان داشتند ولی همگی با گذشت 12 ساعت از جراحی به محدوده طبیعی بازگشتند و این موضوع نشانگر کارآ بودن دریچه­های استفاده شده در این مطالعه بود.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">: پروتز</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مهندسی بافت</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">دریچه قلب</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">آئورت توراسیک</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">فاکتورهای بیوشیمیایی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://eab.journals.pnu.ac.ir/article_1481_5886c0ec94e32b6c363b9506d041d2a3.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
